MAX86141ENP+T Sensores biometrici Optical AFE Optimised pro HR in Applicationibus Carpi.
Product Description
Productum attributum | Precium attributum |
Fabrica: | Maximus Integrated |
Product Category: | Biometric sensoriis |
Notam: | Maximus Integrated |
Sarcina / Case: | TUNICA-WLP-20 |
Packaging: | Reel |
Packaging: | Cut Tape |
Packaging: | MouseReel |
Product Type: | Lorem sensoriis |
Series: | MAX86141 |
Factory Pack Quantity: | 2500 |
Subcategoria: | Sensoriis |
Unitas pondus: | 0.193542 oz |
optimus-in-Class Optical Pulsus Oximeter et Cordis-Rate Sensorem pro Wearable Salutem
MAX86140/MAX86141 potentiae ultra-humilis sunt, omnino integrae, systemata optica data acquirendi.In transmisso latere, MAX86140/ MAX86141 tria programmabilia summo currenti duxerunt coegi qui configurari possunt ad agitare usque ad sex LEDs utentes externo 3x2:1 mux.Cum duobus MAX86140/MAX86141 artibus operantibus in modo servili magistro, aurigae duxerunt ad duodecim LEDs utentes externo 3x2:1 mux.In partem accipientis,
MAX86140 uno canali lectu optico constat, dum MAX86141 duos canales opticos legit, qui simul operari possunt.Meditationes notae condiciones analog ante-finem (AFE) incluso 19-bis ADC habent, industriae plumbeae ambitus ambientis lucis cancellationis (ALC) ac stationem saepes deprehendunt ac munus substituunt.Ob vis humilis consummatio, magnitudo compacta, facilitas usus, et industriae plumbi ambientium levis recusationis capacitas MAX86140/MAX86141, cogitationes ideales sunt pro amplitudine applicationum optical sentiendi, sicut pulsus oximetriae et cordis deprehensio.
MAX86140/MAX86141 operantur in 1.8V copia principalis intentionis et 3.1V ad 5.5V copia coegi ducitur intentione.Ambae cogitationes vexillum SPI interfaciei compatibile sustinent et operationem plene sui iuris.Quaelibet fabrica magnum 128 verbum aedificatum in FIFO habet.MAX86140/MAX86141 praesto est involucrum laganum compactum (WLP) (2.048 x 1.848mm) cum pila pice 0.4mm.
The Single and Dual-Cannel Optical Data Acquisitione System
Optimised Architecture ad Transmissivum et Reflective Cordis Rate vel SpO2 Cras
Minimum Dark Current Vox of <50pA RMS (Sample ad Sample Variance)
Inferius efficax Tenebrae Current Sonitus IMPETRABILIS per Multiplices Samples modos et De-Chip averaging
Summus Consilium, XIX-bit crimen Integrating ADC
Tres Low-Shirt, 8-Bit DUXERIT Current DACs
● Praeclara Dynamic Range > 89dB in White Card Loop-Back Test (Sample-ad-Sample Variance)
Dynamic dolor extendable ad > 104dB pro SPO2 et > 110dB pro HRM cum Multiplici Sample Modi et De Chip averaging
Optimum Ambient dolor et Rejectio Capability
• > 100μA Ambiens Photodetector Current
• > 70dB Ambiens reprobatio apud 120Hz
Ultra-Low-Power Operatio pro Wearable Devices
• Operatio Low-Power, Optical Readout Channel
<10μA (typ) apud 25sps
• Brevis Expositio Integrationis Periodus 14.8µs, 29.4µs, 58.7µs, 117.3μs
• Low Shutdown Current = 0.6μA (typ)
Reprobatio Fast Ambient Vagi
● Miniature 2.048 x 1.848mm, 5 x 4 0.4mm Ball Pitch WLP
● -40°C ad +85°C Operating Temperature Range
Wearable machinae ad Opportunitatem, Hotel et Medical Applications
● Optimized pro Carpi, Digito, Auris, et Aliis Locations
Optimized euismod est deprehendere
• Cordis Rate Optical
• Oxygen Saturation (SpO2)
• Musculus Oxygeni Saturationis (SmO2 et StO2)